Grow Light Planner

Size fixtures for your canopy and check PPFD and DLI against stage targets. Spectrum inputs add red:far-red, blue fraction and crop-steering guidance.

Enter your plants, your light and its height above them to get the hours of light per day they need.

For greenhouses, the DLI Map shows the average sunlight DLI at any location by month, and the grow light needed to reach the target.

About this tool: PPFD, DLI, and choosing a light
About this tool: PPFD, DLI, and choosing a light

Lux vs PPFD

Lux meters measure what the human eye sees. Photosynthesis uses photons from 400 to 700 nm, measured as PPFD. No direct conversion exists between the two.

DLI

DLI is PPFD summed over a day (photons per square meter per day). PPFD is a rate (photons per square meter per second). Plants respond to the daily total.

DLI = PPFD × hours × 0.0036

Sunlight adds to the DLI in a greenhouse or by a window. The DLI Map gives the monthly average from the sun for any location.

Crop and stageTarget DLI
Seedlings and cuttings6 to 12
Tomato, pepper and eggplant transplants15 to 20
Lettuce and leafy greens12 to 17
Basil12 to 17
Other herbs8 to 12
Tomatoes, peppers, cucumbers25 to 30
Cannabis vegetative30 to 45
Cannabis flowering30 to 45

Seedlings and transplants: Purdue. Lettuce: Cornell. Fruiting crops: Michigan State. Cannabis vegetative: NC State and UConn trials. Basil, other herbs and cannabis flowering: Bizon estimates (sources).

Measuring PPFD

Measure at canopy height in the center and at each corner. Edges read lower than the center.

Light saturation

Above the saturation point, more light no longer increases photosynthesis and can cause bleaching and leaf scorch.

Spectrum

Blue keeps plants compact, red is the most efficient per watt, far-red makes stems stretch, and green reaches deepest into the canopy. The total amount of light matters more than its color.

Far-red

PPFD and DLI here are 400 to 700 nm, the range every target uses. Far-red (700 to 750 nm) also drives photosynthesis when combined with shorter wavelengths, so when your light has far-red, Advanced also shows ePPFD and eDLI (400 to 750 nm). They are a proposed extension, not a standard, and are not graded. A far-red bar adds to ePPFD, not PPFD (sources).

Fixture efficacy

Compare µmol/J, not watts. Most LED fixtures run about 2.3 to 3. The number depends on the diodes, the driver, the optics and the spectrum, and a whiter, bluer light gives fewer µmol per joule than a red-heavy one. Use the spec sheet for your fixture (sources).