VPD Chart & Calculator

Vapor pressure deficit (VPD) is how hard the air pulls water out of a leaf. Set the room's temperature and humidity, and how much cooler the leaves run than the air, to get leaf VPD and where it sits against the target for a growth stage or a target of your own.

78 °F 60% Leaf temperature

Without leaf temperature, the readout and chart show air VPD. Leaves can sit a few degrees below or above air temperature, so adding a leaf reading gives the VPD at the leaf.

Below the target range In the target range Above the target range

The same reading as the sliders above. Water evaporates inside the leaf, where the air spaces are saturated at leaf temperature, and leaves through the stomata into drier air. The bigger the gap in vapor pressure, the harder the pull.

Water vapor moving from the saturated air spaces inside a leaf, through a stoma and the boundary layer, to the surrounding air. Inside the leaf Air spaces near 100% RH at leaf temperature Holds 3.06 kPa Boundary layer Stoma Water vapor Surrounding air 78 °F at 60% RH Holds 2.02 kPa Leaf VPD 1.04 kPa Air VPD 1.31 kPa

About VPD: leaf VPD, air VPD and dew point

Air VPD

Air at a given temperature can hold a set amount of water vapor, its saturation vapor pressure. Relative humidity is how much of that it holds now. Air VPD is the difference: saturation pressure × (1 − RH/100).

Leaf VPD

The inside of a leaf is saturated at the leaf's temperature, so the pull on the leaf is the leaf's saturation pressure minus the vapor pressure in the air. When the canopy is 2 °C cooler than the air, leaf VPD is lower than air VPD: about 0.36 kPa lower at 25 °C air, at any humidity. A room run to an air VPD target with cool leaves gives the leaves a lower VPD than the target.

Formula

Saturation vapor pressure uses the Tetens equation: 0.6108 × e17.27T / (T + 237.3) kPa, with T in °C.

Dew point

Any surface colder than the dew point gets wet. Leaves, walls and windows that drop below it at lights-off are where mildew and botrytis start.

Related Tools

Environment Dashboard

Bizon sensors log air temperature, humidity, leaf temperature and VPD around the clock. See the dashboard with sample data.

See the demo

PPFD and DLI Calculator

Average PPFD and daily light integral from your fixtures, checked against targets for the crop and stage.

Open the calculator

EC & PPM Converter

Convert EC to ppm and back on the 500, 640 and 700 scales, with temperature correction.

Open the converter

Sprayer Calibration Calculator

Gallons per acre from nozzle output, speed and spacing, plus how much product goes in the tank.

Open the calculator